Dropping point

ASTM D566 IP 132 ISO 2176 DIN 51801-1 DROPPING POINT OF LUBRICATING GREASE
This test method covers the determination of the dropping point of lubricating grease.
This test method is not recommended for use at bath temperatures above 288°C (550°F). For higher temperatures Test Method D 2265 should be used.

ASTM D4950 STANDARD CLASSIFICTION AND SPECIFICATIONS FOR AUTOMOTIVE SERVICE GREASES

Dropping pointDROPPING POINT

Consists of a nickel-plated brass casing, test tube with projection cap and cork ring, thermometer depth gage, cup plug gage, cover of anticorodal, a polished metal rod Ø1.5x150mm dia., 400ml beaker, heating device unit with motor stirrer.

Technical specifications:
– Temperature: from ambient to 290°C (554°F)
– Power supply: 220V 50/60Hz
– Power: 600W
– Dimensions: 18x21x52 cm
– Weight: 3 kg