Free Water in LPG Apparatus

EN 15469 FREE WATER IN LIQUEFIED PETROLEUM GAS BY VISUAL INSPECTION
This test method covers the use of a pressure cylinder to determine the presence of free water in liquefied petroleum gas (LPG) by visual inspection below 0°C (32°F).

FREE WATER IN LPG APPARATUSFree water in LPG apparatus

Tubular chamber made of acrylic resins 250 ml. capacity, metallic headers coupled stainless steel tierods, neoprene gaskets, fitted with a inlet bottom valve and a top vent valve, hole for thermometer. Tested at 15 bar hydraulic pressure.

Tagged on: